Clean Water Disinfection APPLICATION NOTES

  1. Disinfection In Drinking Water: Choosing The Right Chlorine Analyzer For Your Application
    4/13/2017

    Disinfection is a very important part of the drinking water treatment process, and choosing between an amperometric and colorimetric chlorine analyser is a decision that depends on a variety of factors. Below you will find out why a colorimetric analyser was the right choice for our customer, given their specific situation.

  2. Importance Of Measuring UV Transmittance (UVT) For UV Disinfection
    2/1/2013

    UV disinfection systems disinfect water using UV light at the 254 nm wavelength. UV light at this wavelength actually destroys the DNA of microbiological material in the water which prevents dangerous viruses such as cryptosporidium and e-coli from reproducing and causing harm.

  3. Monitoring Chloramination Using The APA6000™ Ammonia/Monochloramine Analyzer
    7/16/2012

    Chloramination, a process often used for disinfection of drinking water and wastewater, involves mixing chlorine and ammonia to form chloramines. The relative concentrations of both chlorine and ammonia are essential for optimum disinfection. 

  4. Comparison of UV vs. Sodium Hypochlorite (Fact Sheet)
    11/23/2011

    Hypochlorite has some significant environmental concerns associated with DBPs and residual toxicity.

  5. Flow Meter Enhances Chlorination System Performance For Municipal Water Department
    2/16/2016

    The water municipality at a mid-size city in the Western region of the U.S. serving a population of about180,000 people needed to address a chlorine disinfection system problem at one of its water treatment plants.

  6. Disinfection By-Products (DBP) Precursor Monitoring
    2/1/2013

    Chlorine has long been used as a primary disinfection method for many water and wastewater treatment applications. However, there is growing concern about the harmful DBP’s produced by the use of chlorine.

  7. Benefits Of UV Transmittance (UVT) Field Testing For Selling & Servicing UV Disinfection Systems
    2/1/2013

    The Real UV254 'P' series portable meters can be used to measure UV transmittance (UVT) in a number of situations, and are especially beneficially when working with small UV disinfection systems. The following cases outline two situations in which Real Tech's portable meters are invaluable.

  8. Chlorine Method For UKAS Accreditation And DWI Compliance At Welsh Water
    4/13/2017

    In 2013 the Drinking Water Inspectorate for England & Wales announced that water samples collected in England and Wales must be tested in a laboratory that meets specific standards for drinking water sampling and analysis. At the time of the new instruction, the chlorine method employed at the Welsh Water Bretton laboratory was unable to meet these requirements, notably for the prescribed limit of detection. This prompted the laboratory to investigate new analytical options for monitoring residual chlorine.

  9. Removal Of Chloramines With Activated Carbon
    12/30/2013

    In order to reduce the formation of harmful disinfection byproducts in drinking water, alternative disinfectant use has become increasingly widespread. Monochloramine is a leading alternative disinfectant that offers advantages for municipal water. This tech brief details the removal of monochloramine using activated carbon.

  10. Free Chlorine Measurement In Drinking Water Treatment
    12/21/2005

    Before water can be used as a safe and reliable source for drinking water, it must be properly treated. Since water is a universal solvent, it comes in contact with several different pathogens, some of which are potentially lethal, and inactivation is accomplished through chemical disinfection and mechanical filtration treatment. This treatment consists of coarse filtration to remove large objects and pre-treatment which includes disinfection using chlorine or ozone