Drinking Water Treatment Application Notes

  1. Capturing Ammonia In Flue Gas Condensate Treatment For Biomass Power Stations With 3M™ Liqui-Cel™ Membrane Contactors
    8/10/2017

    Heat and power generation in biofuel engine cogeneration plants has become increasingly important as process industries look for more economical and environmentally friendly ways to produce energy.

  2. Application Note: Employing Best Water Quality Monitoring Practices To Reduce Runoff During Construction
    8/4/2011
    Under proposed EPA stormwater runoff guidelines, construction site operators will be required to actively monitor or sample stormwater discharges daily. The enhanced effluent rules take effect in August 2011 for construction sites that disturb 20 or more acres and February 2014 for sites that disturb 10 or more acres, and they may stipulate a strict numerical limit of less than 280 NTU for average turbidity (sediment in water) on any day. By YSI
  3. Improved Efficiencies In TOC Wastewater Analysis For Standard Method 5310B And EPA Method 415
    10/16/2014
    Total organic carbon (TOC) measurement is of vital importance to the operation of water treatment due to organic compounds comprising a large group of water pollutants. TOC has been around for many years, and although it is a relatively simple analysis in theory, operational efficiency is paramount.
  4. On-Line Phosphorous Measurement Takes The Guesswork Out Of Alum Treatment
    7/16/2013

    Phosphorous promotes eutrophication in surface waters and helps create conditions for algal blooming and oxygen depletion. Some phosphorous removal can occur naturally in a conventional biological wastewater treatment facility, but the result is not reliably compliant with increasingly strict limits on permissible phosphate levels in effluent discharged to receiving streams, ponds and lakes. By Bob Dabkowski, Hach Company

  5. The Basics: ORP and Free Chlorine Monitoring
    5/13/2014

    Oxidation Reduction Potential or Redox is the activity or strength of oxidizers and reducers in relation to their concentration. Oxidizers accept electrons, reducers lose electrons. Examples of oxidizers are: chlorine, hydrogen peroxide, bromine, ozone, and chlorine dioxide. Examples of reducers are sodium sulfite, sodium bisulfate and hydrogen sulfide. Like acidity and alkalinity, the increase of one is at the expense of the other.

  6. NEOSEP® Membrane Bioreactor System Simplifies 'Fundamental Necessities' Of MBR
    1/17/2014

    The NEOSEP® MBR system features Kruger’s uniquely designed K-120C and K-240C flat sheet membrane modules.  The modules offer several innovative design features that enhance ease of installation, operation and maintenance.  This includes an integrated central lifting eye, offering an incredibly well balanced module that makes installation and retrieval a simple and stress-free process.

  7. Protecting Pumps From Dead Head Conditions
    4/6/2017

    The C445 motor management relay offers the most configurable protection options in the industry, with features specifically designed to protect critical pumps from costly damages due to dead-head and other underloaded or starved pump conditions.

  8. Application Note: Real-Time Monitoring-Through Swell And High Water
    6/9/2011
    Application article about water quality monitoring pontoon providing continuous data in the Burry Inlet, an estuary in Wales. By YSI
  9. Control Of Active Chlorine Disinfection By-Products (DBPs) Of Drinking Water Using The THM Plus Method
    4/13/2017

    Determining trihalomethane levels using standard analytical methods requires expensive equipment and highly qualified personnel, which also means that analysis costs are very high. For these reasons, trihalomethane analysis poses a serious problem for companies that supply drinking water. Read the full application note to learn how two drinking water laboratories improved quality control of water delivered to end users.

  10. Operations And LRV Calculations At Southwest Pipeline Project Drinking Water Treatment Facility
    4/14/2016

    This presentation will discuss the operation of a 4 MGD pressurized two-stage Ultrafiltration (UF) plant over a 14 month period at the Oliver-Mercer-North Dunn (OMND) Drinking Water Treatment Facility, North Dakota.