Drinking Water Measurement White Papers and Case Studies

  1. Flow Data Red Flags: When To Act
    12/20/2017

    Accurate flow measurement is critical to most water and wastewater processes. Red flags may pop up to indicate meter problems, but which ones should lead you to act — and when? The answer depends on the type of meter, what it is used for, and whether the readings are local or remote.

  2. Precision Air/Gas Flow Measurement Helps Turn Landfills Into Green Electric Power Generators
    12/1/2017

    A leading supplier of landfill gas extraction and recovery systems located in the Midwest region of the US relies on flow meters from Fluid Components International (FCI) for gas flow measurements in landfills. The company has developed hundreds of landfill gas system flares and extraction system skids that are in operation worldwide, which all require accurate gas flow measurement.

  3. Improving Flow Measurement Accuracy With Flow Conditioners
    12/1/2017

    When looking for a way to reduce plant operating costs, one of the potentially simplest and often least expensive solutions is to measure liquid and gas flow more accurately. Plant upgrade projects that focus on the continuous improvement of flow measurement and control can trim overall production costs by eliminating waste and reducing maintenance costs.

  4. Advancing Thermal Mass Gas Flow Meters For 21st Century Process And Plant Needs
    12/5/2017

    Process, instrument and plant engineers are challenged continuously by productivity and plant operating efficiency objectives as well as ensuring plant compliance with an ever expanding list of regulations.

  5. Bulk Emergency Chlorine Vapor Scrubber System Restored For Oklahoma City
    9/19/2017

    As a bulk emergency chlorine vapor scrubber system approached the end of its anticipated 20-year useful life, the city engaged Integrity Municipal Systems, LLC (IMS) inspected the equipment and proposed a system refurbishment plan that would ensure proper system performance and safe storage of the 30,000 gallons of corrosive caustic soda contained within it.

  6. Meter Technology Used For Verification
    11/13/2015

    The core of Coriolis mass flowmeters are oscillating tubes. As soon as mass is flowing through them, a Coriolis force is affecting the oscillation, creating a phase shift.

  7. Improving Wastewater Treatment With Air Flow Instrumentation
    12/7/2017

    In wastewater treatment plants, a variety of processes are employed to eliminate organic pollutants from water to ensure its safety and release for future uses. One of the most common processes is the activated sludge method, which biologically treats the wastewater through the use of large aeration basins.

  8. Is There A Correlation Between ATP And Other Traditional Microbiological Methods?
    12/7/2017

    Perhaps the most common question that we’re asked is how our ATP tests correlate with traditional microbiological methods.  Unsurprisingly, when people are used to getting their information in a certain way, they naturally want to know how a new method will stack up against it.  However, the mechanisms of culture-based techniques and ATP analyses are completely different, and in many ways, so are the results they produce. 

  9. Clearing Up Misconceptions About Turbidimeter Performance And Calibration
    4/19/2018

    There is little doubt about the importance of taking turbidity readings as part of drinking water treatment. However, there are certain misperceptions about the associated requirements and procedures needed to confirm the validity of those readings. The major points of confusion seem to revolve around perception of the terms “approved,” “calibration,” and “validation.” Here is a quick synopsis on what you really need to know about meeting U.S. EPA Method 180.1: Determination of Turbidity by Nephelometry for accurate turbidity readings.

  10. Verify Fluid Flow To Your Analyzer And Keep Your Plant Running
    12/4/2017

    No matter how sophisticated a fluid analyzer system may be, it will be ineffective if a sample flow fails to reach the analyzer sensor or if the sample is contaminated or stale.