Wastewater Application Notes
-
Chlorine Measurement In Wastewater And Regulated Discharge Requirements
8/8/2014
Homes, industry, schools, and businesses all generate sanitary waste, or sewage. Sewage treatment is a multistage process that cleans up wastewater before discharge or reuse. In the final step of the treatment, disinfectants are added to kill disease-causing organisms. Common disinfectants are chlorine gas and sodium hypochlorite. Chlorine dosage levels are designed to leave almost no residual in the wastewater after treatment
-
Orion DUAL STARâ„¢ Quick Start Note - Nitrate In Water & Wastewater
7/31/2009
The Thermo Scientific Orion DUAL STAR meter shows the results of both input channels simultaneously.
-
Take Control Of Your Water Distribution Network With Digitalization And Remote Monitoring
5/19/2022
Any process plant constantly generates a high volume of status data. Today, this data can be extracted from the plant, stored, analyzed, and prepared to meet operator needs and lower marginal costs.
-
Sewage Pump Station Level Application
10/1/2019
The most common level application in the water and waste water industry is the infamous wet well. With its line-of-sight measurement technology, rugged sensor, narrow laser beam and virtually nonexistent maintenance requirements or on-site calibration, ABB’s LLT100 laser level transmitter answers most concerns related to wet well level measurements and makes it easy to calculate what could amount to a substantial return on investment.
-
WWTP Utilizes Online Instrumentation And SCADA To Keep Operating Costs Low And Effluent Quality High
2/6/2013
Providing the best value to wastewater customers requires a team of operators that have a deep sense of ownership and are committed to continuous improvement. Such is the case for the operating staff at one wastewater treatment plant whose progressive attitude and a philosophy of “do it right” led them to an investment in online instrumentation and SCADA for compliance, monitoring, and control.
-
Biosolids Odor And Corrosion Control
7/8/2024
For more than 20 years, USP Technologies’ comprehensive biosolids odor and corrosion control solutions have been extremely effective at reducing sulfides and other odor causing compounds in municipal and industrial wastewater treatment systems.
-
Mapping And Identifying The Source Of Water Quality Issues
6/28/2017
A Southern U.S. municipality experiencing taste and odor issues in a certain neighborhood was also having difficulty maintaining chlorine residual levels in the area. Biological growth was suspected, however, water leaving the treatment plant met and exceeded all water quality requirements. After several investigations, the source of contamination in the distribution system could still not be identified.
-
Background And Summary Of Tests For The 2000PV Restraint
4/13/2021
The 2000PV is a restraint for PVC pipe and the standardized mechanical joint. This product is the result of years of testing and evaluation and its performance has been proven by thousands of hours of proof tests, as well as third-party evaluations. This report describes the 2000PV through the 12" size.
-
Flow Monitoring In The Partially Filled Discharge Of A Rainwater Retention Basin
9/19/2022
Read about managing water discharge into a mixed water drainage system, electromagnetic flow measurement of water loads, and automated discharge control by way of a structure with overflow.
-
Alcoholic Beverage Fusel Alcohol Testing With Static Headspace
9/2/2014
A static headspace method was developed using Teledyne Tekmar automated headspace vial samplers to meet the method requirements of the Alcohol and Tobacco Tax and Trade Bureau of the US Department of the Treasury (TTB) method SSD: TM:2001 for testing fusel alcohols in alcoholic beverages.