Wastewater Analysis Solutions
-
Improving Compliance Through Real-Time Phosphorus Control
4/18/2017
Levels of phosphorus, a chemical element that promotes organic growth, must be controlled in wastewater coming from beverage, food and dairy processing plants. Failure to control phosphorus accurately has a negative impact on water quality and can lead to large fines.
-
Advances In Paper-Based Devices For Water Quality Analysis
2/22/2017
Water quality test strips have been around for decades. They are usually constructed from a porous media, including different types of paper, and undergo a color change when dipped into water containing the analyte of interest. These test strips have seen application in swimming pools, aquariums, hot tubs, remediation sites, and other commercial/environmental areas.
-
Capital Controls® Series 17T2000 Amperometric Titrator
10/22/2015
The Series 17T2000 Amperometric Titrator is an analytical instrument for the electrical determination of the end point of a titration for free, combined, or total chlorine residual. It can also be used to determine bromine, iodine, ozone, permanganate, and chlorine dioxide residuals.
-
Capital Controls® Series NXT3000 High Capacity Gas Feed System
10/15/2015
The Series NXT3000 High Capacity Gas Feed System is a family of vacuum-operated, solution-feed, gas dispensing components including a vacuum regulator, meter assembly and ejector to meet customer needs for feeding chlorine, sulfur dioxide, ammonia or carbon dioxide gas. The Series NXT3000 is a versatile, high quality system which operates at sonic conditions eliminating the need for differential pressure regulation across the rate control valve.
-
Capital Controls® Series 70CV2000 Chloromatic™ Gas Control Valve
10/8/2015
The Series 70CV2000 Chloromatic™ control valve is wall mounted and responds to control signals from a water flow transmitter and/or a chlorine residual analyzer controller. Valve characteristics are provided to directly accept a pacing signal proportional to flow.
-
Capital Controls® Series NXT3000 Gas Feed System
10/8/2015
The Series NXT3000 Gas Feed System is a family of vacuum-operated, solution-feed gas dispensing components including a vacuum regulator, meter assembly, and a selection of ejectors to meet customer needs for feeding chlorine, sulfur dioxide, ammonia or carbon dioxide gas. The Series NXT3000 is a versatile, high quality system which operates at sonic conditions eliminating the need for regulating differential pressure across the rate control valve. Proven design, rugged construction, and the use of the best available materials assures precise gas feeding, low maintenance and dependable operation for the life of the equipment.
-
Ammonium Analyzer Liquiline System CA80AM
9/1/2015
Liquiline System CA80AM offers high-precision ammonium measurement in all critical control points. As member of the Liquiline platform, it enables plug & play and easy upgrade to a measuring station - minimizing the installation effort. Automatic calibration and cleaning as well as the low consumption of reagents save you operating and maintenance costs. Advanced diagnostics with remote access ensure process safety and support you in providing process documentation to the authorities.
-
Determination Of Polycyclic Aromatic Hydrocarbons In Seafood
4/20/2015
Polycyclic Aromatic Hydrocarbons (PAHs) are a large group of organic compounds found naturally in the environment. PAHs are monitored by the US Environmental Protection Agency due to their carcinogenic characteristics.
-
Determination Of Hexanal In Foods Utilizing Dynamic Headspace
4/9/2015
Hexanal is one of many well-documented aromatic components that contribute to flavor and aroma in common consumer food products containing omega-6 fatty acids. Hexanal content is also used to measure the oxidative status of foods rich in omega-6 fatty acids.
-
Analyzing Total Organic Carbon In Sea Water
4/2/2015
The analysis of Total Organic Carbon (TOC) in seawater can be both challenging and expensive. The concentration of organic carbon in seawater is of considerable interest. The effect this matrix can have on TOC analyzers can lead to rapid consumable turnover, costly maintenance and repairs.