Drinking Water Application Notes
-
How To Read An Encoder
9/13/2013
The HR-E LCD encoder has a 9-digit Liquid Crystal Display (LCD) to show consumption, flow and alarm information. The display automatically toggles between 9-digit and 6-digit consumption, rate of flow and meter model.
-
Hemodialysis Patient Health
10/29/2021
Controlling dialysate quality is critically important to hemodialysis patient health. Complications as minor as nausea and fatigue or as severe as metabolic acidosis and sepsis can result if dialysate composition is incorrect. All the factors that ultimately affect dialysate composition must therefore be carefully monitored and controlled: proper proportioning and mixing of concentrates with water; the quality of water mixed with concentrates to form dialysate; and the quality of water used in the reprocessing of hemodialyzers, system maintenance and disinfection.
-
Real-Time Water Quality Data For Agriculture
9/23/2020
We arm farmers with mission-critical water data to help enhance crop yield and taste. KETOS delivers valuable insights for fluctuations in deficiency and toxicity.
-
Flexible Expansion Joints Provide Protection For Pipelines Subject To Subtle Or Sudden Movement
12/7/2020
Flex-Tend flexible expansion joints have a proven record of providing protection for pipelines subject to subtle or sudden movement. As with all products used in the water and wastewater industry, protection is optimized with the selection of the proper assembly incorporated into a sound design. This paper is intended to provide assistance in both of these areas.
-
Active Energy Control – Energy Reductions Of Up To 10% Above Standard Drives
4/1/2017
Energy costs continue to increase. At the same time, there is increased pressure to reduce utility bills without sacrificing operations or comfort.
-
Improved Determination Of Volatile Organic Compounds In Water By SPME And GC/MS
6/21/2018
The analysis of water for volatile organic compounds is important due to their toxicity. The current methods for this determination lack of sensitivity, selectivity or capability for automation. This paper presents the new ISO 17943 Standard using Solid Phase Microextraction (SPME) and GC/MS. The sample preparation by SPME enables limits of detection and easy automation of the whole method. GC/MS provides the required sensitivity and selectivity. This ISO Standard was validated by an interlaboratory trial, which results confirm the outstanding performance for this method.
-
Activated Carbon And Adsorption Of Trichloroethylene (TCE) And Tetrachloroethylene (PCE)
12/30/2013
Trichloroethylene (TCE) and Tetrachloroethylene (PCE) are two of the most common solvents that contaminate groundwater supplies in the United States. Both solvents see frequent use in the extraction of fat, in the textile industry, in the production of various pharmaceutical and chemical products. TCE is also used as a degreaser from fabricated metal parts, and PCE serves as a component of aerosol dry-cleaning solvents.
-
Application Note: Busseron Creek Watershed Partnership Addresses Concerns In A Rural Watershed
1/20/2010
As with other watershed organizations, the Busseron Creek Watershed Partnership (BCWP) exists because of surface water quality degradation. In this case, those waters drain 163,231 acres of a watershed that crosses the boundaries of Vigo, Clay, Green, and Sullivan counties in West- Central Indiana. By YSI
-
Solution For Algae Blooms
12/17/2015
Harmsco® Filtration Products is pleased to offer a solution to the ever increasing blue-algae blooms in water sources. A multi-barrier approach is necessary to physically remove intact (algae and cyanobacteria) before they rupture in the treatment process and then remove extracellular cyanobacteria through adsorption.
-
Application Note: Ozone Measurement In Potable Water
3/1/2010
Ozone is a powerful oxidizing agent that can be used to destroy the organic compounds that affect the taste and odor of potable water. Environmental concerns have led to increased use of ozone because, unlike chlorine, it does not form hazardous by-products.