Product/Service

Disinfection: TCL Total Chlorine Analyzer

Source: Emerson

Total chlorine measurement is essential in the control of chlorine in water before its return to the environment in a wide range of industrial applications including desalination. It also provides accurate reporting to the EPA about that control. To meet EPA requirements, the instrument must be reliable for long periods of time and monitor down to 500 ppb. The Rosemount Total Chlorine Measurement system from Emerson meets and exceeds all requirements while saving money through the use of low-cost reagents.

The Rosemount TCL from Emerson, a complete system for measuring total chlorine in water, employs low-cost reagents – white distilled vinegar and potassium iodide – saving significant money and time. The system requires reagent change only every two months – a dramatic reduction over other total chlorine systems. The TCL also uses a low flow rate (less than 6 gal per day), which is a real advantage in areas where drainage is limited and/or water usage is an issue. The complete system incorporates a sample conditioning and measuring system for the continuous determination of total chlorine in water. The conditioning system continuously pumps acetic acid and potassium iodide into the sample. The sensor measures the iodine concentration, and the analyzer displays the total oxidant concentration in ppm as CL2. With no metal wetted parts, it is ideal for seawater and measures samples having alkalinity as great as 300ppm.


DOW Terneuzen, The Netherlands. Total Chlorine Analyzers Improve the Monitoring and Control of Chlorine in Cooling Water Prior to Its Return to the Sea.

INSTRUMENTATION: Total Chlorine Measurement
 TCL Sample Conditioning System
  • NO METAL WETTED PARTS. Ideal for seawater
  • LOW SAMPLE FLOW (about 15 mL/minute) means little waste
  • REAGENT-BASED SYSTEM measures true total chlorine
  • FIVE GALLONS OF REAGENT lasts two months

 

1056-24 Chlorine Analyzer
  • LARGE, BACK-LIT DISPLAY with easy to use interface.
  • TWO INDEPENDENT OUTPUTS
  • THREE FULLY PROGRAMMABLE ALARMS
  • INPUT FILTER improves stability at low concentrations

 

56 Chlorine Analyzer
  • FOUR-LINE, FULL-COLOR DISPLAY WITH EASY-TO-USE INTERFACE
  • FOUR FULLY PROGRAMMABLE OUTPUTS AND RELAYS
  • HART® DIGITAL COMMUNICATIONS STANDARD
  • DATA LOGGER AND GRAPHICAL DISPLAY STANDARD
  • INFORMATION SCREENS AND TROUBLESHOOTING HELP available at a touch of a button

 

499A CL-02 Sensor
  • MEMBRANE-COVERED AMPEROMETRIC SENSOR
  • NO TOOLS REQUIRED to change membrane
  • MAINTENANCE TAKES ONLY A FEW MINUTES a month
  • VARIOPOL CONNECTOR OPTION allows the sensor to be replaced without removing and rewiring cable